verifica codice errore F3274 mismatch fabric encapsulation (moquery -c faultInst -f ‘fault.Inst.code==”F3274″‘)
25.01 2023 | by massimilianoverifica codice errore F3274 mismatch fabric encapsulation apic1# moquery -c faultInst -f ‘fault.Inst.code==”F3274″‘ Total Objects shown: 20 # fault.Inst […]
verifica codice errore F3274 mismatch fabric encapsulation
apic1# moquery -c faultInst -f ‘fault.Inst.code==”F3274″‘
Total Objects shown: 20
# fault.Inst
code : F3274
ack : no
annotation :
cause : fabric-encap-mismatch
changeSet : fabEncMismatchVlans (New: 106), fabEncMismatchVlansSet (New: failed)
childAction :
created : 2022-01-22T00:04:54.270+00:00
delegated : yes
descr : VNID mismatch between peers detected for encap vlans (106).
dn : topology/pod-1/node-103/sys/vpc/inst/dom-103/if-346/fault-F3274
Nota: si tratta del VPC346
domain : infra
extMngdBy : undefined
highestSeverity : critical
lastTransition : 2022-01-22T00:07:03.668+00:00
lc : raised
modTs : never
occur : 1
origSeverity : critical
prevSeverity : critical
rn : fault-F3274
rule : vpc-if-if-fabric-encap-mismatch
severity : critical
status :
subject : if-fabric-encap-mismatch
type : config
uid :
# fault.Inst
code : F3274
ack : no
annotation :
cause : fabric-encap-mismatch
changeSet : fabEncMismatchVlans (New: 105-106)
childAction :
created : 2022-01-21T21:50:56.614+00:00
delegated : yes
descr : VNID mismatch between peers detected for encap vlans (105-106).
dn : topology/pod-1/node-103/sys/vpc/inst/dom-103/if-685/fault-F3274
Nota: si tratta del VPC685
domain : infra
extMngdBy : undefined
highestSeverity : critical
lastTransition : 2022-01-22T00:07:03.668+00:00
lc : raised
modTs : never
occur : 2
origSeverity : critical
prevSeverity : cleared
rn : fault-F3274
rule : vpc-if-if-fabric-encap-mismatch
severity : critical
status :
subject : if-fabric-encap-mismatch
type : config
uid :
# fault.Inst
code : F3274
ack : no
annotation :
cause : fabric-encap-mismatch
changeSet : fabEncMismatchVlans (New: 101,901)
childAction :
created : 2022-01-22T00:04:43.082+00:00
delegated : yes
descr : VNID mismatch between peers detected for encap vlans (101,901).
dn : topology/pod-1/node-102/sys/vpc/inst/dom-101/if-2/fault-F3274
Nota: si tratta del VPC2
domain : infra
extMngdBy : undefined
highestSeverity : critical
lastTransition : 2022-01-22T00:07:03.557+00:00
lc : raised
modTs : never
occur : 1
origSeverity : critical
prevSeverity : critical
rn : fault-F3274
rule : vpc-if-if-fabric-encap-mismatch
severity : critical
status :
subject : if-fabric-encap-mismatch
type : config
uid :